ČSN ISO 11799 - Informace a dokumentace - Požadavky na ukládání archivních a knihovních dokumentů
INTERNATIONAL
STANDARD
ISO
11799
First edition
2003-09-15
Information and documentation — Document storage requirements for archive and library materials
Contents
Page
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Site of the building
5 Construction of the building
6 Installation and equipment
7 Use
8 Disaster-control plan
9 Exhibitions
Annex A (informative) Maximum limits tolerance for air pollutants
Annex B (informative) Recommended climatic conditions for the long-term storage of archive and library materials
Annex C (informative) Disaster preparedness
Bibliography
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the
International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11799 was prepared by Technical Committee ISO/TC 46, Information and documentation.
Introduction
Archives and libraries are institutions established by society in order to collect, preserve and make available
documents intended for consultation, by viewing directly or via a screen, or, in the case of sound recordings,
by ear.
Archive and library collections normally contain material in a wide variety of formats. These are mainly paper-
based books, manuscripts, files, records, maps and graphic collections, but may also include vellum,
parchment, papyrus, film, photographic materials, audiovisual material, magnetic and optical media, and
machine-readable formats. All these materials ideally require specific storage conditions.
Documents for current use may require different storage conditions from those requiring long-term or indefinite
preservation.
This International Standard applies to the long-term storage of archive and library materials, but takes into
account that, as the materials are stored to allow current use as well, some compromise with the ideal
conditions for long-term storage may be unavoidable.
Depending on the climate and economic situation of a country, it may be difficult to create and maintain ideal
conditions for the long-term storage of archive and library materials.
Figures and quantities given in this International Standard are intended for general international guidance.
This International Standard presents some facts and general rules which should be considered when a
building for the purpose of archival storage is newly constructed, when an old building originally designed for
another use is converted, or when a building already in use for this purpose is renovated.
Information and documentation — Document storage requirements for archive and library materials
1 Scope
This International Standard specifies the characteristics of general-purpose repositories used for the long-term
storage of archive and library materials. It covers the sitting and construction of the building and the
installation and equipment to be used.
It applies to all archive and library materials held in general-purpose repositories, where mixed media may be
stored together. It does not preclude the establishment of separate areas or compartments within individual
repositories, where the environment can be controlled to create conditions suiting the needs of specific
archive materials.
It does not cover special requirements for the long-term storage of not or not fully paper-based documents
such as parchment or vellum, photographic documents or machine-readable documents.
It also does not cover repository management procedures.
In a number of fields, national or local building regulations may cover in detail such matters as construction,
safety and security for public buildings and buildings in which valuable objects are stored (fire precautions,
emergency exits, security against earthquakes, theft, burglary, terrorist acts, etc.), as well as services and
equipment in professional use. This International Standard therefore avoids detailed rules and regulations in
these fields, except when recommending what may be additions to these requirements.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
ISO 9706:1994, Information and documentation — Paper for documents — Requirements for permanence
ISO 12606:1997, Cinematography — Care and preservation of magnetic audio recordings for motion pictures
and television
ISO 18902, Imaging materials — Processed photographic films, plates and papers — Filing enclosures and
storage containers
ISO 18911, Imaging materials — Processed safety photographic films — Storage practices
ISO 18918:2000, Imaging materials — Processed photographic plates — Storage practices
ISO 18920:2000, Imaging materials — Processed photographic reflection prints — Storage practices
ISO 18923:2000, Imaging materials — Polyester base magnetic tape — Storage practices
ISO 18925, Imaging materials — Optical disc media — Storage practices
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
archive and library materials
all types of documents kept in archives and libraries, mainly books, manuscripts, files, records, maps, graphic
collections and other documents consisting of paper, but also parchment, papyrus, films, photographic
materials, audiovisual recordings, magnetic and optical media, as well as bindings and protective material
3.2
document
recorded information or material object which can be treated as a unit in a documentation process
3.3
long-term storage
storage, for a period of undefined length, of material kept for permanent retention
3.4
repository
building or room designed or arranged and used specifically and exclusively for long-term storage of archive
and library materials
4 Site of the building
The site for an archive and/or library repository building should not be
liable to subsidence or flooding,
especially at risk from earthquakes, tidal waves or landslides,
at risk from fire or explosions in adjacent sites,
near a place or a building which attracts rodents, insects and other pests,
near a plant or installation emitting harmful gases, smoke, dust, etc.,
in an especially polluted area, nor
near a strategic installation which could be a target in an armed conflict.
If these requirements cannot be met, special provision shall be made in the construction of the building to
defend against these threats.
In order to minimize the harmful effects of exposure to sunlight, careful attention should be paid to orientation,
landscaping and the site’s microclimate.
5 Construction of the building
5.1 Self-containment and security
The repository shall be secured against theft, burglary, vandalism and terrorism. Precautions should be taken
against arson. The repository shall be either a purpose-built detached building or a self-contained unit within a
building. There shall be only one entrance for visitors. Precautions shall be taken against any other entrances
being used by unauthorized people.
NOTE 1 For more information on precautions against arson, see reference [1] in the Bibliography.
Emergency exits shall be constructed in such a way that they can easily be opened from the inside and that
they cannot be opened from the outside.
NOTE 2 National regulations regarding exits may apply.
In the interests of security and climatic inertia, and also in order to protect archive and library materials from
exposure to harmful light, the storage areas should have no windows. If there are windows, they shall be fitted
in such a way as to exclude direct daylight (see also 6.5).
5.2 Climatic inertia
The repository should be designed to provide an accurate and stable internal environment, with minimum
dependence on mechanical systems. This can be partially achieved by constructing the external walls, roof
and floor of the building from materials that, as far as possible, insulate the interior from external climatic
changes.
Walls, floors and ceilings inside the repository should be made of materials that have a high thermal capacity.
In areas of the world where the relative humidity does not exceed the recommended values for prolonged
periods of time, building materials with a high hygroscopic capacity are also recommended (see 6.7).
NOTE 1 For example, brick is a material with both high thermal and high hygroscopic capacity.
NOTE 2 For more information on climatic inertia, see reference [2] in the Bibliography.
5.3 Inner structure and load
For reasons of fire safety and efficient climate control, the area used as a repository should be divided into
compartments.
NOTE 1 The maximum size of a fire compartment is normally given in national regulations.
The walls (including doors), floors and ceilings between single rooms and compartments, and between
storage and other areas of the building shall be constructed so as to prevent fire (and water) from spreading
into a neighbouring unit. A minimum of 2 h of fire resistance is recommended. Doors should be self-closing
and should normally be kept in a closed position. Where it becomes necessary to keep doors open under
normal use, they should be fitted with magnetic hold-open devices which release to permit automatic door
closing upon activation of the building fire alarm/detection system. Door sills should be avoided unless
absolutely essential (for example for flood prevention), in which case ramps should be provided.
The materials used for all inside surfaces shall not be combustible nor emit, attract or retain dust. Nor shall
they be liable, through decomposition in the event of fire or for other reasons, to emit substances harmful to
the materials stored, e.g. acidic gases. The choice of material shall minimize, in the case of fire, the emission
of harmful substances, smoke and soot.
NOTE 2 Methods to test the surface-burning characteristics of building materials (flame spread and smoke generation)
are given in references [3] and [4] in the Bibliography.
When constructing the floors, it shall be taken into account that densely stored archive and library materials
can have a considerable weight. A structural engineer should calculate and recommend floor-loading
requirements based on the density and quantity of the materials stored.
6 Installation and equipment
Use the following International Standards whenever possible: ISO 12606, ISO 18911, ISO 18918, ISO 18920,
ISO 18923, ISO 18925.
6.1 Services
Supply systems for electricity, gas, and especially for water, shall not be located in or near a room in the
repository, unless needed in that room for a specific function directly connected with the collections.
Installations providing temperature/humidity control, air filtration and ventilation systems shall be connected to
a central plant room. This room shall not be in the same fire compartment as the storage area, and should
preferably be in a separate building.
6.2 Fire detection system
All parts of the building shall be provided with a fire detection system connected to a central monitoring panel.
Such a system shall respond automatically to the presence of fire by detecting smoke or other products of
combustion. Heat detection devices shall only be installed as the sole method of detection in areas such as
plant rooms where other types of detectors may be inappropriate or unsuitable. All parts of the building shall,
in addition, be provided with manually operated fire-alarm call points which can be used by occupants to
indicate the presence of a fire.
The operation of the detection system shall result in the following actions:
a local warning at the control panel and/or repeater panels, indicating where a fire has been detected;
operation of plant shut-down, such as air conditioning or heating systems;
automatic transmission of a warning to the local fire brigade or central alarm station;
general fire-alarm warning throughout the repository building.
The central fire-alarm control panel should provide a facility to monitor all components of the system and
should visually display the status of the system. Panels should be located in a convenient, central location
which is continuously manned or is manned while the repository is occupied or open. Where the panel is not
located at or near the probable fire-brigade entry point, a supplementary or repeater panel should be provided
for the use of the fire brigade.
NOTE National or local fire-alarm codes may apply.
6.3 Fire extinguishing system
Consideration should be given to the benefits offered by an automatic fire fighting system. Gas- or water-
based fire fighting systems are accepted in repositories.
Where automatic fire extinguishing systems are used, they shall be regularly inspected and maintained. They
shall be designed to minimize damage to archive and library materials from fire and fire-suppression action.
NOTE 1 Properly designed, installed and maintained sprinkler systems do far less damage than manually fighting a fire
that has not been contained by a sprinkler system. Possible malfunction of a sprinkler system, however, may cause
severe damage to documents.
NOTE 2 Water-mist systems currently being researched for library and archive use apply small amounts of water at
very high pressure and may offer a substantial advantage over conventional sprinkler systems. A principal advantage of
water mist is that, when correctly designed and installed, all the water discharged should turn to vapour and leave virtually
no residual water. Research is still in progress to determine whether water-mist systems are effective in high-density
storage systems utilizing compact shelving or in repositories employing very high shelving.
Where water-based fire protection systems are to be installed, provision shall be made for rapid drainage from
all protected spaces. Shafts, staircases and drains should be so configured that water leaving one space does
not enter another. Intermediate floors in multi-storey repositories should be waterproofed.
Gas systems shall only be used for small compartments, i.e. discrete spaces which can be made airtight.
Halon gases are excluded for environmental reasons. Carbon dioxide should not be used for rooms normally
occupied by people.
NOTE 3 New fire-extinguishing gases without the same environmental impact as the original halon gases have been
and are being developed.
Where an automatic fire extinguishing system is not to be provided, the following shall be installed:
hose reels or racks in such a position that all parts of the building are within 6 m of the nozzle of a fully
extended hose;
hydrant systems or rising mains on all buildings more than 30 m in height or where a single floor exceeds
1 000 m2. The hydrant or rising mains should be located so as to permit the fire brigade to pressurize the
pipework from outside the building.
These installations are also recommended as backup systems to an automatic fire extinguishing system.
A smoke extraction system is recommended.
Portable fire extinguishers shall always be available, even if an automatic fire suppression system has been
installed. Hand-held extinguishers shall be strategically placed. Staff should be trained in the proper use of fire
extinguishers. If they are expected to use fire hoses, they should also be trained in their proper use.
Gas and water are suitable. Water extinguishers should never be used on fires in electrical equipment.
6.4 Intruder alarm
A monitored intruder-alarm system should be provided.
6.5 Illumination
The damage caused by light is cumulative. Intensity, duration and spectral distribution of any illumination in a
repository should be controlled to minimize damage.
A repository room shall not be illuminated more than is necessary for retrieval and replacement of documents,
room inspection and cleaning. For the two latter purposes, an illumination of about 200 lx on the floor level is
suggested. Direct daylight should be excluded. In a building not primarily designed as a repository, but
adapted for that purpose, windows shall ideally be blocked up, or as a minimum be screened by curtains or
blinds, and/or by UV filtering on the window glass.
Similar screening provisions are recommended for offices, public reading rooms and any other room in which
documents are consulted.
Illumination shall be provided by one of the following:
fluorescent lamps fitted with diffusers. If the emitted radiation contains a relative ultraviolet component of
more than 75 µW/lm, each lamp shall be fitted with an ultraviolet filter that diminishes the relative
ultraviolet radiation (with a wavelength below 400 nm) to below that level;
incandescent light fitted with heat-absorbing filters. The minimum distance between the lamp and an item
on a shelf shall be 500 mm;
fibre-optic lighting systems, with the light-generating unit placed well away from the object to be
illuminated.
NOTE 1 The ratio between radiant flux with a wavelength shorter than 400 nm (i.e. ultraviolet radiation), and the total
luminous flux, is measured in microwatts per lumen (µW/lm). With a view to preservation of documents, the accepted
maximum limit for ultraviolet radiation is 75 µW/lm.
NOTE 2 Fluorescent lamps fitted with diffusers or fibre-optic lighting are preferred. At present, fibre-optic lighting is only
feasible for exhibition purposes.
There shall be separate switches for the illumination of each of the sections that the repository is naturally
divided into.
At an easily accessible place outside the repository, there should be a central switch indicating whether all
lights and other electrical circuits in the repository are turned off.
6.6 Ventilation and air quality
The repository shall be ventilated in such a way as to allow free circulation of air throughout, and to prevent a
build-up of pockets of high relative humidity.
If this does not occur naturally, a ventilation system should be provided. There should be fresh air intake, the
amount depending on local circumstances.
Specific attention should be given to ventilation around and within the shelving. To ensure this there shall be a
distance of at least 150 mm between the floor and the lowest shelf, as well as between the average line of
upper edges of objects stored on the top shelf and the ceiling. There shall also be a distance of at least
50 mm between the top of the highest document on each shelf and the bottom of the shelf above. Gangways
and aisles also allow ventilation (see also 6.8).
The air in a repository should be kept free of air pollution, acidic and oxidizing gases and dust. Suggested
maximum levels of the most common air pollutants are listed in informative Annex A. It shall be taken into
account that some materials such as plastics for wrapping, paints and coatings for walls and shelves, etc. may
emit noxious gases not only when burning (see 5.3. and 6.8.), but also by degassing and decomposing. When
choosing materials for building, furniture and equipment, the amount of off-gassing should be taken into
account. A certain time lapse (up to a couple of weeks, when the off-gassing of new materials is the highest)
before putting new buildings, furniture and equipment into use is also advisable.
NOTE Photographic, audiovisual and magnetic media are particularly sensitive to oxidizing pollutants, dusty air and/or
other active compounds. Optical disks are also sensitive to oxidizing agents. Separate storage for these materials is
usually necessary because of their lower temperature and humidity requirements, and because of the degradation
products they give off.
The air quality inside the repository should be monitored regularly for acidic and oxidizing gases and dust. The
frequency should be such that seasonal or other repeated variations are discovered. This will make any
irregular variation stand out more clearly.
If a filter system is used, materials used for filtration shall in themselves not be damaging to the documents.
Filter systems shall be regularly maintained.
6.7 Room climate
Repositories for archive and library materials should be kept at a cool temperature, ideally controlled in a
building constructed according to the principles of climatic inertia (see 5.2).
Repositories for archive and library materials shall be kept at a relative humidity below the point where
microbiological activity occurs.
NOTE According to the present state of knowledge, there is an increasing risk of microbiological activity above 60 %
relative humidity, and increased brittleness at a very low relative humidity. The lowest acceptable humidity for long-term
storage of archive and library materials is under discussion. For different kinds of materials, different limits are
recommended, but there is no general agreement, either upon temperature or upon humidity. It has been established that
materials last longer at lower temperatures and at lower relative humidity. As a guidance, the data in informative Annex B
may be used.
Sharp fluctuations in temperature and relative humidity put stress on archive and library materials and should
therefore be avoided. The aim shall be to achieve as stable a temperature and relative humidity as is
practicable.
There shall be monitoring devices for temperature and humidity, preferably recording instruments that register
conditions at different times and in different seasons. Sensors should be sited to provide readings that
represent the storage areas, but account should also be taken of any extreme or abnormal conditions which
may be present, e.g. near outside walls or close to a source of heating or ventilation.
The monitoring instruments shall be calibrated and recalibrated according to the manufacturer's instruction.
When material is taken out of cold storage, it shall be acclimatized. In order to avoid expansion and
contraction, measures shall be taken to ensure that the material absorbs or gives off as little moisture as
needed to equilibrate with its new climatic conditions. Special attention shall be paid to the danger of
approaching the dew point at the surface of an item, if it is moved to a warmer room or inside an airtight
container (glass, plastics) when such items are relocated from cold storage.
When moving an item from a cool to a warm room, satisfactory acclimatization can be achieved by placing it in
an airtight enclosure with a minimum air volume until the temperature has risen to the ambient temperature.
When moving an item in an airtight enclosure back to cold storage, the enclosure should not be removed for a
while, until the item has acclimatized.
6.8 Furniture and equipment
No furniture or equipment other than that used for storage and handling of documents shall be in a repository.
Furniture or equipment used shall have no sharp edges or corners, nor protrusions on the sides adjacent to
the stored items and shall not damage documents upon contact.
The materials used for furniture or equipment shall not be combustible nor emit, attract or retain dust. Nor
shall they be liable, through decomposition in the event of fire or for other reasons, e.g. natural ageing, to emit
substances harmful to the materials stored, e.g. acidic gases. The choice of material shall minimize, in the
case of fire, the emission of harmful substances, smoke and soot.
For the correct functioning of the principles of climatic inertia (see 5.2.), no furniture nor any other item shall
be placed in close proximity to an outside wall. There should be a distance of at least 200 mm between items
and wall.
The load-bearing capacity of shelving shall be sufficient to carry their load (see 5.3). The shelves should be
large enough to ensure that documents will not protrude beyond the edges.
Shelves for normal storage, e.g. of books, shall be fitted in such a way that the material will stand upright
when required. The items shall be able to be stored close together, but not so close that items cannot be
easily removed. Equipment for this purpose shall be easily adjustable. For books and paper documents, the
lateral or vertical pressure on an individual item should not exceed 350 Pa for normal objects and 150 Pa for
electrostatic copies.
NOTE A pressure of 350 Pa roughly corresponds to that received by a book lying horizontally, on which a book of
similar size and 45 mm thick has been placed.
In order to allow easy access for normal and emergency use, and to allow air circulation, ample space should
be left between the shelves (or blocks of shelving) and between shelves (or blocks of shelving) and walls (see
also 6.6). If, for reasons of security, the shelves are subject to limited access, this should be effected by
materials allowing air circulation, such as a grill or a punched plate. In order to protect the materials, facilitate
use, and minimize danger in emergency situations, the height of the shelving should never exceed 215 cm.
7 Use
7.1 General
In a repository for archive and library materials, smoking, eating and drinking shall be strictly forbidden.
Activities not related to storage shall not take place. Only archive and library materials shall be stored there
(with the exception of disaster recovery equipment and materials).
For security reasons, telephone extensions or other communication systems should be present in each
compartment of the repository.
Use the following International Standards whenever possible: ISO 12606, ISO 18911, ISO 18918, ISO 18920,
ISO 18923, ISO 18925.
7.2 Cleaning and disinfection
The repository, its air-handling systems and the items stored shall be cleaned regularly. Cleaning agents shall
not be harmful to the materials stored.
The items in the repository shall be free from biological infestation. Documents received for the first time from
outside shall be examined before being placed in the repository. Any item suspected of being infested should
receive disinfective treatment, as well as the stack area and shelving in the place where the infestation has
been detected. Cleaning shall be carried out using vacuum cleaners fitted with filters retaining fungal spores.
All methods of disinfection using chemicals or radiation are likely to be damaging to the materials. Deep
freezing should be considered as a treatment for insect infestation.
An isolation room shall be used for inspection, cleaning and interim storage of documents which may be
infected.
7.3 Protection
All documents shall be protected. The degree of protection required depends on the state of the documents
and the amount of use they are likely to receive.
Bindings and custom-built boxes, as well as document boxes, folders or containers provide effective means of
protecting the documents. Any protective covering should enclose and support the items without exerting
undue pressure.
The protective device shall not carry original information which is not also in the document.
Paper for protective material in direct contact with documents shall fulfil the conditions of ISO 9706.
Protective material shall not contain plasticizer nor emit acidic or otherwise noxious gases.
For storage of photographic materials, which are not within the scope of this International Standard,
ISO 18902 applies. ISO 18902 may also be valid for other dyestuff-based copies (e.g. blueprints).
No uncoated metal surface shall be in direct contact with stored items. The coating shall not be combustible
nor emit, attract or retain dust. Nor shall it be liable, through decomposition in the event of fire or for other
reasons, to emit substances harmful to the documents stored, e.g. acidic gases. The choice of material shall
minimize, in the case of fire, the emission of harmful substances, smoke and soot.
7.4 Storage position
Books shall be stored upright on the tail edge. Volumes with a height over 400 mm should be stored flat. If
they are placed on top of one another, their weight shall be taken into account. There shall be no excessive
pressure on the volume at the bottom (see Note to 6.8) and it shall be possible to remove and replace it easily.
NOTE Easy handling will hardly be possible if more than three items are placed on top of one another, and if the
height of such a stack exceeds 150 mm.
Single sheets (maps, posters, graphic art, drawings), shall always be well protected. Large formats should be
stored flat in protective enclosures such as boxes, drawers or custom housing. Single-sheet items that are
large or vulnerable should be placed in individual folders or mats within the enclosures. Outsized items, too
large to be accommodated in such an enclosure, may be rolled if the document material is sufficiently robust
to withstand rolling.
8 Disaster-control plan
For a proper system of indefinite storage, a risk-assessment and disaster-preparedness plan pertinent to the
specific building and collections shall be established, and all staff should be familiar with it. For elements of
such a plan, see informative Annex C and items [7] to [10] in the Bibliography.
9 Exhibitions
Generally, for exhibitions the same requirements regarding room climate, security, etc. as for document
repositories apply. Exhibitions put documents at increased risk, and shall therefore be restricted to a minimum.
Items should not be permanently on exhibition.
Being on exhibition means that the surface of a document is exposed to extensive periods of light.
Furthermore, the damage done by light to a document is cumulative. Consequently, both the intensity and the
duration of light exposure on a document on exhibition shall be reduced to a minimum. This is especially
necessary for the most sensitive items such as modern writing inks, acidic groundwood paper, colour
photographs, coloured prints and drawings, etc. A light level of 50 lx on the displayed document is sufficient
for viewing, if ambient light levels are lower and sufficient time is allowed for the viewer's eyes to adjust to the
lower light level. No incandescent light, nor any other heat-generating light source, shall be placed inside or
close to a showcase.
NOTE Curtains on the showcases, which are opened only when a visitor is inspecting the items, may reduce the time
of exposure to light. Light switches outside a showcase or an exhibition cabinet, which can be turned on by the viewer and
are turned off automatically after a suitable time, fulfil the same purpose.
For documents required repeatedly for exhibition, a facsimile substitute should be provided.
Annex A
(informative)
Maximum limits tolerance for air pollutants
Table A.1
Maximum limits tolerance
Type of pollutants
volume fraction × 109
µg/m3
Sulfur dioxide (SO2)
5 to 10 —
Nitrogen oxides (NOx)
5 to 10 —
Ozone (O3)
5 to 10 —
Acetic acid (CH3COOH)
< 4
—
Formaldehyde (HCHO)
< 4
—
Dust particles, including mould spores — 50
NOTE 1 The limit for dust particles presupposes a removal by the air filtration system of 60 % to 80 % of the dust particles
with a diameter of more than 0,5 µ.
NOTE 2 The first three figures are taken from reference [5] in the Bibliography, where a discussion of the practicality, given
the current air-filtration technology, is included.
NOTE 3 The levels for acetic acid and formaldehyde are based on experience from the US National Archives.
NOTE 4 Volume fraction 10−9 is equal to a part per billion by volume.
Annex B
(informative)
Recommended climatic conditions for the long-term storage of
archive and library materials
Very generally speaking, lowering the temperature and/or lowering the relative humidity will lengthen the life of
the documents. However, other effects may run counter to this, notably condensation if the temperature sinks
below the dew point, and substrate brittleness when the relative humidity becomes low. The figures in
Table B.1 are compiled from different sources, mainly from other standards, see Clause 2 and items [5] and
[6] in the Bibliography. It is strongly recommended that these publications be consulted for more details about
areas of application, alternative storage conditions for different purposes, etc. To enhance the usefulness of
this annex, data on materials outside the scope of this International Standard are included. For documents
made of paper, parchment and leather, and for diverse varieties of gramophone discs and some magnetic
media, no International Standards on document storage exist. The figures in Table B.1 for such material types
are taken from other referenced documents, and it may be possible to find alternative climatic conditions
recommended in other publications. In any case, and for all types of materials, the archive or library should
choose its climatic level, also taking into account the nature and value of the documents as the financial costs
of keeping temperature and humidity levels low.
Requirements relating to climatic conditions for materials that are to be heavily and often used, and which
therefore cannot be subject to an acclimatization process, will differ from the figures in Table B.1. Maximum
document longevity and maximum readiness for use are two different options, that in many cases are mutually
exclusive. In Table B.1, an exception from the long-life option is made for paper documents in regular use, for
which such climatic data are given that will promote paper suppleness more than paper longevity. Paper
suppleness, due to a higher water content adsorbed on the paper fibres, will minimize mechanical damage to
the paper caused by handling, but it will make chemical deterioration proceed faster.
Table B.1 — Recommended climatic conditions for the long-term storage of archive
and library materials
Temperature Relative humidity
°C %
Type of materials
min. max. Tolerable
daily
changes
within the
limits
min. max. Tolerable
daily
changes
within the
limits
Paper, optimum preservation
2 18
± 1
30 45
± 3
Paper, staffed stack areas, items in regular use
14 18
± 1
35 50
± 3
Parchment, leather
2 18
± 1
50 60
± 3
Photographic film: black and white silver gelatin on cellulose
acetate base:
EITHER
2
± 2
20 50
± 5
OR
5
± 2
20 40
± 5
OR
7
± 2
20 30
± 5
Photographic film: black and white silver gelatin or silver dye
bleach on polyester base
21
± 2
20 50
± 5
Table B.1 (continued)
Temperature Relative humidity
°C %
Type of materials
min. max. Tolerable
daily
changes
within the
limits
min. max. Tolerable
daily
changes
within the
limits
Photographic film: colour (chromogenic) on cellulose acetate
base:
EITHER
− 10 ± 2
20 50
± 5
OR
− 3
± 2
20 40
± 5
OR
2
± 2
20 30
± 5
Photographic plates: black and white, silver gelatin
18
± 2
30 40
± 5
Photographic paper prints: black and white silver gelatin or
silver dye bleach or diazo
18
± 2
30 50
± 5
Photographic paper prints: colour (chromogenic)
2
± 2
30 40
± 5
Photographic paper prints: all other prints
− 3
± 2
30 50
± 5
Microfilm: black and white silver gelatin, on cellulose acetate
base
EITHER
2
± 2
20 50
± 5
OR
5
± 2
20 40
± 5
OR
7
± 2
20 30
± 5
Microfilm: black and white silver gelatin on polyester base or
thermally processed silver on polyester base or vesicular on
polyester base
21
± 2
20 50
± 5
Gramophone discs (acetate, shellac, vinyl)
16 20
± 2
30 40
± 5
Magnetic tape (data, audio, video) on polyester base
EITHER
8 11
± 2
15 50
± 5
OR
8 17
± 2
15 30
± 5
OR
8 23
± 2
15 20
± 5
Magnetic media (other)
12 18
± 2
30 40
± 3
Optical disks
− 10 23
No data
as yet
available
20 50 ± 10
NOTE 1 Care should be taken to ensure proper encapsulation and proper acclimatization when low storage temperatures and/or low
relative humidities are chosen, see 6.7.
NOTE 2 This table does not include data on acceptable long-term climatic changes, since very little is known with certainty except
that it should be avoided. For paper records, item [5] in the Bibliography suggests that, on top of the daily fluctuation, a maximum
monthly drift of 1,5 °C and 3 % relative humidity is acceptable, all within the absolute maximum and minimum limits.
NOTE 3 For mixed-media collections, e.g. paper and parchment stored together, a compromise value of temperature and relative
humidity will have to be found.
Annex C
(informative)
Disaster preparedness
It is recommended that contingency plans to meet the disaster threat should include the following:
liaison with the emergency fire services so that they understand the special concern archives and libraries
have for water damage to their collections;
a plan or an outline of the building;
location details of the rare and most important items in the collections, and where any concentration of
such material may be;
contact telephone numbers for the Disaster Coordination Officer;
contact telephone numbers for conservation expertise, a conservator working with, or for, the institution;
contact telephone numbers for a person qualified to advise on the salvage of damaged archive or library
materials;
names and telephone numbers of staff who can be contacted outside normal working hours;
telephone numbers of institutions who may be sympathetic and able to provide additional manpower in an
emergency, e.g. neighbouring institutions, militia;
telephone numbers of companies and institutions able to provide containers suitable for carrying and
freezing damaged materials;
telephone numbers of companies and institutions able to provide deep freezing facilities;
telephone numbers of companies and institutions able to supply dehumidifying equipment;
telephone numbers of companies offering wrapping materials.
This list is not exhaustive.
For further information, see references [7] to [10] in the Bibliography.
Bibliography
[1] National Fire Protection Association (NFPA; Quincy, MA, USA) Standard 909: Standard for the
Protection of Cultural Resources (Libraries, Museums, Places of Worship and Historic Properties),
1997
[2] CHRISTOFFERSEN, Lars D., Zephyr: Passive climate controlled repositories: Storage facilities for
museum, archive and library purposes. Lund: Lund University, Department of Building Physics, 1996.
139 pp. ISRN LUTVDG/TVBH-96/3028 – SE(1-139). ISBN 91-88722-06-6
[3] National Fire Protection Association (NFPA; Quincy, MA, USA) Standard 255: Standard Method of
Test of Surface Burning Characteristics of Building Materials
[4] American Standard Test Method (ASTM) Designation E 84
[5] WILSON, William K., Environmental guidelines for the storage of paper records: a technical report
sponsored by the National Information Standards Organisation (USA). Bethesda, Maryland: NISO
Press, 1995. 21 pp. NISO Technical Report: 1. ISRN NISO-TR01-1995. ISBN 1-880124-21-1
[6] PICKETT, Andrew G., Preservation and storage of sound recordings: A study supported by a grant from
the Rockefeller Foundation, by A.G. Pickett and M.M. Lemcoe. Washington, DC: Library of Congress,
1959, 74 pp
[7] ANDERSON, Hazel and MCINTYRE, John E., Planning manual for disaster control in Scottish libraries
and record offices. Edinburgh: National Library of Scotland, 1985
[8] BARTON, John P. and WELLHEISER, Johanna G. (eds.), An ounce of prevention: a handbook on disaster
contingency planning for archives, libraries and record centres. Toronto: Toronto Area Archivist Group,
1995
[9] BUCHANAN, Sally, Disaster planning, preparedness and recovery for libraries and archives: a RAMP
study with guidelines. Paris: UNESCO, 1988. vi, 187 pp
[10] FORTSON, Judith, Disaster planning and recovery: a how-to-do-it manual for librarians and archivists.
New York: Neal-Schuman, 1992. ix, 181 pp. ISBN 1-55570-059-4
[11] BOSTON, George (ed): Safeguarding the documentary heritage: a guide to standards, recommended
practices and reference literature related to the preservation of documents of all kinds. Paris:
UNESCO, 1998. Memory of the WorId Programme, CII-98/WS/4
[12] La Conservation — Principes et réalités, Ouvrage collectif réalisé sous la direction de Jean-Paul
Oddos, Paris: Éditions du Cercle de la librairie, 1995, collection Bibliothèques. 405 pp.
ISBN 2-7654-0592-1
[13] CHARDOT, Paul, Le Contrôle climatique dans les bibliothèques. Paris: Direction du livre et de la lecture.
1989
[14] IFLA, Principles for the care and handling of library material, compiled and edited by Edward P.
Adcock with the assistance of Marie-Thérèse Varlamoff and Virginie Kremp. IFLA PAC (International
Preservation Issues, 1), 1998. 72 pp. ISBN 2-912743-00-1
© ISO 2003 — All rights reserved